Blog
Guides on electrical panels, breakers, upgrades and home electrical safety for Gresham homeowners.
Can You Use a Siemens Breaker in an Eaton Panel?
Can you use a Siemens breaker in an Eaton panel? No. Siemens QP breakers are not listed or classified for Eaton BR or CH panels. A QP is 1 inch wide like an Eaton BR, so it can…
Read article
Why Is My Electrical Panel Warm to the Touch? Normal vs Hot
Why is my electrical panel warm to the touch? Slight warmth on the panel door or a few breakers can be normal when heavy loads run, because current always makes a little heat.…
Read article
Are Siemens QP Breakers Compatible With Older ITE Panels?
Are Siemens QP breakers compatible with older ITE panels? Usually yes. Siemens took over ITE's electrical business, and the Q line of plug in breakers continues the ITE design.…
Read article
Can You Install a Subpanel When the Main Panel Is Full? Your Options
Can you install a subpanel when the main panel is full? Often yes. You need two adjacent spaces for the 240 volt feeder breaker, and there are several ways to free them:…
Read article
Are Split Bus Electrical Panels Safe? Risks, Rules and Replacement
Are split bus electrical panels safe? A split bus panel in good condition is not automatically dangerous, but most are now 50 to 60 years old and have real drawbacks. They have…
Read article
Why Won't a Square D Breaker Reset?
Why won't a Square D breaker reset? Most often because it was not pushed all the way to OFF first. A tripped Square D breaker sits in the middle, and it must be pushed firmly…
Read article
Does an Eaton BR Breaker Fit Every Eaton Panel?
Does an Eaton BR breaker fit every Eaton panel? No. Eaton BR breakers fit Eaton BR load centers and many older panels from brands Eaton absorbed, including Cutler-Hammer BR,…
Read article
Are Eaton BR and CH Panels Interchangeable?
Are Eaton BR and CH panels interchangeable? No. They are two separate Eaton load center families. BR panels take 1 inch BR breakers. CH panels take 3/4 inch CH breakers on a…
Read article
Why Does an Electrical Panel Make a Clicking Sound? What Each Click Means
Why does an electrical panel make a clicking sound? A single click is often normal. It can be a breaker tripping, a relay or contactor switching a load, or a smart or timer…
Read article
Can a Subpanel Have a Higher Amp Rating Than the Breaker Feeding It?
Can a subpanel have a higher amp rating than the breaker feeding it? Yes. It is common and fully allowed. The feeder breaker in the main panel protects both the feeder wire and…
Read article
Does a Subpanel Need Separate Neutral and Ground Bars? The Rule Explained
Does a subpanel need separate neutral and ground bars? Yes. In every subpanel the neutral conductors must land on an isolated neutral bar, and the equipment grounds must land…
Read article
Why Does a Circuit Breaker Trip With Nothing Plugged In? Hidden Faults
Why does a circuit breaker trip with nothing plugged in? Because the fault is in the fixed wiring, a hardwired device or the breaker itself. Common causes are a short in a…
Read article
Are GE THQL and THQP Breakers Interchangeable?
Are GE THQL and THQP breakers interchangeable? Not freely. THQL is GE's standard 1 inch plug in breaker. THQP is a half inch thin breaker designed for GE panels whose bus and…
Read article
Does a Subpanel Require a Breaker Hold-Down Kit? When the NEC Says Yes
Does a subpanel require a breaker hold down kit? Only when the subpanel is fed through a backfed breaker. NEC 408.36(D) says a plug in breaker that is backfed must be secured…
Read article
Why Does an Electrical Panel Smell Like Fish? Overheating Explained
Why does an electrical panel smell like fish? Usually because something inside is overheating. Many plastics, wire insulation and breaker housings contain chemicals that give…
Read article
Is Square D QO Better Than Homeline?
Is Square D QO better than Homeline? QO is the premium line and Homeline is the value line, so QO has the edge on features. QO breakers are 3/4 inch wide, have a Visi-Trip red…
Read article
Can You Use a Main Breaker Panel as a Subpanel? Yes, With 3 Changes
Can you use a main breaker panel as a subpanel? Yes, and many electricians prefer it. A main breaker panel works as a subpanel once three things are done: the neutral to ground…
Read article
Why Does a Breaker Trip When It Rains? Finding the Wet Spot
Why does a breaker trip when it rains? Water is getting into something electrical and leaking current to ground. A GFCI breaker or outlet senses that leak and cuts power, often…
Read article
Does an Electrical Panel Need Filler Plates? Why Open Slots Fail Inspection
Does an electrical panel need filler plates? Yes. Every unused breaker opening in the panel cover must be closed with a filler plate, also called a blank or knockout closure.…
Read article
Are Siemens QP and QT Breakers Interchangeable?
Are Siemens QP and QT breakers interchangeable? Partly. QP is Siemens' standard 1 inch plug in breaker. QT is the half size duplex, or tandem, that puts two circuits in one 1…
Read article
Why Won't a Circuit Breaker Stay in the ON Position? Causes and Fixes
Why won't a circuit breaker stay in the ON position? Because it is detecting a problem the moment power returns, or because the breaker itself has failed. A short circuit or…
Read article
Are Eaton BR Breakers Better Than CH Breakers?
Are Eaton BR breakers better than CH breakers? No. CH is Eaton's premium line, and BR is its value line. CH breakers are 3/4 inch wide with a trip flag window, and CH panels…
Read article
Can You Use a Square D Breaker in an Eaton Panel?
Can you use a Square D breaker in an Eaton panel? No. Square D breakers, whether Homeline or QO, are not listed or UL Classified for Eaton BR or CH panels. A Homeline breaker…
Read article
Why Does an Electrical Panel Make a Buzzing Noise? Normal vs Dangerous
Why does an electrical panel make a buzzing noise? A very faint, steady hum can come from normal magnetic vibration under heavy load. A loud buzz, crackle or sizzle is…
Read article
Are Eaton BR and BRH Breakers Interchangeable?
Are Eaton BR and BRH breakers interchangeable? Yes, in the panels that accept BR breakers. BRH breakers are the same 1 inch type BR form factor, with the same clip and fit, but…
Read article
Why Does a Circuit Breaker Trip After 10 Minutes? Overload Explained
Why does a circuit breaker trip after 10 minutes? Almost always because the circuit is overloaded. Breakers have a heat sensing part that trips slowly when current runs a bit…
Read article
Can You Install a Subpanel Outside? Outdoor Panel Rules and Clearances
Can you install a subpanel outside? Yes. The NEC allows outdoor subpanels when the panel is rated for wet locations, usually NEMA 3R, and has proper working clearance and…
Read article
Do I Need a Subpanel in My Garage? Signs, Costs and Options
Do I need a subpanel in my garage? You need one when the main panel has no free spaces and you want several new garage circuits, or when the garage is far from the main panel.…
Read article
Do I Need Conduit for a Subpanel? Indoors, Outdoors and Underground
Do I need conduit for a subpanel? Not always. Inside a house, a subpanel feeder can usually be NM or SER cable, with no conduit. Outdoors, underground and anywhere the wire…
Read article
Do I Need a Sub Panel for a Hot Tub? Disconnects, GFCI and Panel Space
Do I need a sub panel for a hot tub? Usually not. Most hot tubs need a dedicated 240 volt circuit from your main panel and a GFCI spa disconnect near the tub. You only need a…
Read article
Do I Need a Sub Panel in My Shed? One Circuit vs Subpanel
Do I need a sub panel in my shed? Only if the shed needs more than one circuit or any 240 volt load. A shed with lights and a couple of outlets runs fine on a single 20 amp…
Read article
Best Electrical Panel Reddit: What Electricians Actually Recommend
What is the best electrical panel according to Reddit? On r/electricians, r/AskElectricians and r/electrical, the answer keeps coming back to two premium lines: Square D QO and…
Read article
Does a Sub Panel Require 4 Wires? Hots, Neutral and Ground Explained
Does a sub panel require 4 wires? In almost every home, yes. A 120/240 volt sub panel needs two hot wires, a neutral and a separate equipment ground. The only time 3 conductors…
Read article
Do I Need a Ground Rod for a Detached Garage? The One Circuit Rule Explained
Do I need a ground rod for a detached garage? You do if the garage has a subpanel or more than one circuit running to it. If the garage gets a single branch circuit, the NEC…
Read article
Does a Sub Panel Need Its Own Ground Rod? Same Building vs Separate Building
Does a sub panel need its own ground rod? Only if it sits in a separate building. A sub panel in the same house is grounded through the equipment ground wire in its feeder, so…
Read article
Does a Sub Panel Need a Bonding Screw? Why the Green Screw Comes Out
Does a sub panel need a bonding screw? No. A sub panel must not have its bonding screw or bonding strap installed. The neutral bar has to float, isolated from the metal can.…
Read article
Can You Feed a Sub Panel From Another Sub Panel? Rules, Sizing and Wiring
Can you feed a sub panel from another sub panel? Yes. The NEC allows it, and electricians do it all the time. The second panel gets its own breaker in the first panel, its own…
Read article