Do I Need a Sub Panel in My Shed? One Circuit vs Subpanel

Do I need a sub panel in my shed? Only if the shed needs more than one circuit or any 240 volt load. A shed with lights and a couple of outlets runs fine on a single 20 amp circuit. A workshop, a heater, a mini split or a kiln usually needs a small subpanel. Decide by the loads, then size the wire for what you might add later.

Key Takeaways

  • Lights and a few outlets: one 20 amp circuit is enough.
  • Power tools, heat, AC or 240V: plan a subpanel.
  • A subpanel brings a ground rod requirement at the shed.
  • One circuit needs no ground rod, but still needs a disconnect.
  • Trenching is most of the cost. Oversize the first run.
  • Permits apply to shed wiring in Gresham like any other wiring.
Do I need a sub panel in my shed: backyard shed workshop with lights on at dusk

Sheds have changed. They used to hold a mower and a rake. Now they are home offices, art studios, gyms and woodshops. Oregon's rainy months push a lot of hobbies indoors, and the backyard shed becomes a second room.

The power plan has to match. Too little and breakers trip every time the saw starts. Too much and you spend money you did not need to. The right answer comes from a simple list of what you will plug in.

1,920 WSafe continuous load on a 20A, 120V circuit
1,500 WA typical plug-in space heater
18 inPVC conduit burial depth
60ACommon shed subpanel size

Does a Shed Need a Sub Panel?

No, not by code. A shed needs a sub panel only when the loads you plan need more than one circuit or need 240 volts.

The NEC lets a separate building be fed by a single branch circuit. That is the simplest, cheapest way to get power to a shed. The code also allows a feeder and a subpanel. Neither is required. Your loads decide.

How Do You Know What Your Shed Needs?

List every load, add the watts, and check for anything that runs at 240 volts or for hours at a time.

Shed useUsual power plan
Storage, lights, one outletOne 15 or 20 amp circuit
Home office with laptop and lampOne 20 amp circuit
Office plus space heaterTwo circuits or a small subpanel
Woodshop with table saw and dust collectorSubpanel, 60 amp typical
Mini split heat pumpSubpanel or a dedicated 240V circuit
Welder, kiln or saunaSubpanel, 60 to 100 amp

Space heaters are the hidden load. A 1,500 watt heater uses most of a 20 amp circuit by itself. Add a shop vac and the breaker trips. If you want winter heat, plan for it now.

What Does a Single Circuit to a Shed Involve?

One circuit from the house panel, a disconnect at the shed, GFCI protection and buried cable or conduit. No ground rod.

The disconnect can be as simple as a listed switch near the shed door. Outlets need GFCI protection. Outdoor and shed receptacles in damp areas need weather resistant devices and in use covers.

For the run itself, UF cable can be buried directly at 24 inches. A 20 amp, 120 volt GFCI protected residential circuit can go as shallow as 12 inches. PVC conduit needs 18 inches of cover. See do I need conduit for a subpanel for the full depth chart.

What Does a Shed Subpanel Involve?

A feeder breaker in the house panel, a 4 wire feeder, a small panel at the shed, and a grounding electrode, usually two ground rods.

1

Feeder Breaker

A 2 pole breaker in the main panel. 40 to 60 amps covers most sheds.

2

4 Wire Feeder

Two hots, neutral and ground. See why 4 wires.

3

Shed Panel

Main breaker or main lug with a disconnect. Bonding screw out.

4

Ground Rods

Two 8 foot rods tied to the ground bar. See ground rod rules.

Check the main panel first: A shed subpanel needs a free 2 pole space and spare capacity at the house. Older 100 amp panels in Gresham are often already full. That can turn a shed project into a panel upgrade.

How Much Does Power to a Shed Cost?

SetupRough installed range
Single 20A circuit, short run$800 to $2,000
60A subpanel, under 50 feet$1,800 to $3,500
100A subpanel, long run$3,000 to $6,000+
Trenching through concrete or rockAdds $500 to $2,000

These are planning ranges, not quotes. Distance and digging dominate the price. A 60 amp feeder costs only a bit more in wire than a 20 amp circuit, but saves a second trench later.

What Rules Apply to Shed Wiring in Oregon?

  • Electrical permit and inspection, even for one circuit
  • Call 811 before digging, required by Oregon law
  • Disconnect at the shed, readily accessible
  • GFCI protection for shed receptacles
  • Working clearance in front of any panel

Oregon allows homeowners to wire their own property with a permit. Many still hire out the feeder and panel, then finish lights and outlets themselves. Ask your electrician if that split works for your job. Planning a garage panel too? Read do I need a subpanel in my garage.

What Mistakes Do People Make Wiring a Shed?

The big three are undersized wire, the wrong cable underground and skipping the permit. All three cost more to fix than to do right.

Undersized wire is the most common. A long run on 12 gauge wire loses voltage. Saws bog down. LED lights flicker. Chargers run hot. On runs over about 75 feet, bump up a wire size, or two for heavy tools.

The wrong cable is next. Indoor NM cable buried in the yard, or run in conduit outdoors, breaks down from moisture. It can fail years later with no warning. Use UF cable or wet rated wire in conduit. See conduit for a subpanel.

Then the permit. An unpermitted shed circuit can cause trouble when you sell the house. Home inspectors in the Portland metro area often flag backyard wiring with no permit record. A permit costs far less than redoing the work for a sale.

One more. Do not tie a shed rod to the neutral. Ground rods always land on the ground bar, and the neutral bar stays isolated.

How we wrote this: We checked NEC 2023 sections 210.8, 225.30, 225.31, 250.32 and Table 300.5, plus Oregon permit and 811 requirements.

FAQ

Can I run an extension cord to my shed?

Only temporarily. Extension cords are not permanent wiring and are a fire and shock risk when buried or left outside.

What size subpanel do I need for a shed?

Most sheds are well served by a 60 amp subpanel. Workshops with welders or heat may need 100 amps.

Do I need a ground rod at my shed?

Only if it has a subpanel or more than one circuit. One circuit needs no rod.

Can I put a mini split on a shed circuit?

Small mini splits need a dedicated 240V circuit. If the shed also needs lights and outlets, a subpanel is the clean solution.

Do I need a permit to run power to a shed?

Yes. Any new circuit or feeder needs an electrical permit and inspection in Gresham.