Does a Sub Panel Need a Bonding Screw? Why the Green Screw Comes Out

Does a sub panel need a bonding screw? No. A sub panel must not have its bonding screw or bonding strap installed. The neutral bar has to float, isolated from the metal can. Only the main service panel gets the green screw. Leave it in a sub panel and normal neutral current runs on your ground wires, which is a real shock hazard.

Key Takeaways

  • The bonding screw ties the neutral bar to the panel enclosure.
  • It belongs in the main panel, the service disconnect, and nowhere else.
  • In a sub panel, remove it or never install it. NEC 250.24(A)(5) and 250.142(B).
  • Sub panels need a separate ground bar bonded to the can.
  • A detached building does not change the rule. Its ground rod connects to the ground bar.
  • New panels often ship with the screw in a bag. Read the label.
Does a sub panel need a bonding screw: open panel with neutral bar and green bonding screw

You open the box on a new load center. Inside is a little green screw. Sometimes it is taped to the label. Sometimes it is already threaded into the neutral bar. The instructions say it is "for service equipment use only." So what do you do with it in a subpanel?

You leave it out. That one screw decides whether your panel is wired as a main panel or as a sub panel. Get it wrong and the panel will still turn on. Everything will still seem to work. That is exactly why this mistake is so common, and so dangerous.

1Place neutral and ground may bond
250.24NEC section that sets the rule
2 barsNeutral and ground, kept apart
GreenColor of most bonding screws

What Is a Bonding Screw in an Electrical Panel?

A bonding screw is a green screw that passes through the neutral bar into the metal panel enclosure. It electrically joins neutral and ground at that panel.

Some panels use a bonding strap instead. It is a flat metal link from the neutral bar to the can. Same job. Either one is called the main bonding jumper when it is used at the service.

That connection is required in one place. It creates the path that lets a ground fault return to the utility transformer fast. A big fault current trips the breaker in a fraction of a second. Without that path, a fault could leave metal parts live.

Does a Sub Panel Need a Bonding Screw?

No. In a sub panel the bonding screw or strap must be removed. The neutral bar stays isolated from the enclosure.

NEC 250.24(A)(5) says no grounded conductor, meaning the neutral, may be connected to equipment grounding on the load side of the service disconnect. NEC 250.142(B) repeats the idea for equipment. A sub panel is always on the load side. So the bond is not allowed there.

Panel typeBonding screw or strap
Main service panelRequired. Neutral bonded to enclosure
Sub panel, same buildingMust be removed. Neutral floats
Sub panel, detached buildingMust be removed on new 4 wire feeds
Main breaker panel used as a subMust be removed
Meter main with panel after itBond at the meter main only

That last row trips up a lot of people. Many Gresham homes built in the last 20 years have an outdoor meter main with a disconnect. Inside, the big panel in the garage looks like a main panel. It is not. It is a sub panel, and its neutral should float.

Why Is a Bonded Sub Panel Dangerous?

A bond in a sub panel puts normal neutral current onto ground wires, metal boxes, conduit and pipes. Those parts can carry voltage you can feel.

Electricity takes every path back to the source. With the neutral bonded in the sub, the neutral wire and the ground wire run in parallel. Current splits between them. Now the ground wire carries current all day long.

That causes three problems. Metal enclosures and conduit can sit a few volts above true ground. GFCI and AFCI breakers can nuisance trip. And if the neutral ever loosens, the ground path carries all of it. Someone touching a dryer and a water pipe at the same time becomes part of the circuit.

Warning: Do not open a panel to check for the screw yourself unless the main is off and you know the panel. The lugs at the top stay live even with the main breaker off.

Does the Main Panel Need a Green Bonding Screw?

Yes. The service disconnect panel must have its main bonding jumper installed. That is usually the green screw or strap.

NEC 250.24(B) and 250.28 require it. It is the only point where neutral meets ground in the whole house. Leaving it out of the main panel is just as wrong as leaving it in a sub. Without it, a ground fault may not trip the breaker at all.

If you are not sure which of your panels is the service disconnect, look for where the utility wires land. The first disconnect after the meter is the service disconnect. Everything after it is a sub panel.

How Should a Sub Panel Be Set Up Instead?

1

Remove the Bond

Take out the green screw or strap. Bag it and leave it in the panel for the inspector.

2

Add a Ground Bar

Install the manufacturer's ground bar kit, bonded directly to the enclosure.

3

Land the Feeder

Hots on the lugs. Neutral on the neutral bar. Feeder ground on the ground bar.

4

Split Every Circuit

White wires to the neutral bar. Bare and green wires to the ground bar. No mixing.

That setup needs a 4 wire feeder. Two hots, a neutral and a ground. We explain why in does a sub panel require 4 wires. If you are chaining panels, the same setup repeats in each one, as covered in can you feed a sub panel from another sub panel.

What About Sub Panels in Detached Garages and Sheds?

New detached building feeds use 4 wires, so the sub panel stays unbonded. The ground rod connects to the ground bar, not the neutral.

Before the 2008 NEC, a detached building could be fed with 3 wires and the neutral bonded at the building. Some of those installs still exist and may be allowed to stay. Any new feeder, or a rewired old one, must use 4 wires and no bond. See do I need a ground rod for a detached garage for the electrode side.

Spotted a green screw in your subpanel? It is a fast fix for a licensed electrician, often under an hour. If the panel itself is old or full, it may be time to look at a Gresham electrical panel upgrade.

How we wrote this: We checked NEC 2023 sections 250.24, 250.28, 250.32 and 250.142, and the bonding instructions printed in Square D, Eaton and Siemens load centers.

FAQ

Can I just leave the bonding screw in the bag?

Yes. Many electricians leave it bagged inside the panel so the inspector can see it was not installed.

Is the bonding screw the same as the ground screw?

No. Ground screws hold ground wires to the ground bar or box. The bonding screw joins the neutral bar to the enclosure.

What happens if a sub panel is bonded?

Neutral current flows on ground paths. It can energize metal parts, cause GFCI trips and fail inspection.

Does a main lug sub panel come bonded?

Many come with the screw or strap installed at the factory for service use. Always check and remove it for sub panel use.

Does a transfer switch panel need a bond?

It depends on whether the generator is a separately derived system. Ask an electrician, because the answer changes the wiring.

Need an electrician in Gresham?

Panel upgrades, repairs, rewiring and more. Call for a free estimate.

Call (833) 804 1966
Call (833) 804 1966