The electrical panel brands most often called bad are Federal Pacific Electric (Stab-Lok), Zinsco, some Challenger panels and old Pushmatic panels. Inspectors and insurers flag them.
- Federal Pacific Stab-Lok: Independent tests found many breakers failed to trip when overloaded.
- Zinsco and Sylvania: Breakers can fuse to the aluminum bus bar and stay on during a fault.
- Challenger: Certain 1980s models had overheating breakers and a GFCI breaker recall.
- Pushmatic: Very old, stiff breakers with no clear trip indication and no main breaker in some units.
Many insurers refuse to cover or renew homes with these panels until they are replaced. Brand is not the only problem: any panel with heat damage, rust or loose breakers needs attention.